Resultados 1 - 20 de 101
Filtrar
2.
ASAIO J ; 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38165978

RESUMEN

Microfluidic membrane oxygenators are designed to mimic branching vasculature of the native lung during extracorporeal lung support. To date, scaling of such devices to achieve clinically relevant blood flow and lung support has been a limitation. We evaluated a novel multilayer microfluidic blood oxygenator (BLOx) capable of supporting 750-800 ml/min blood flow versus a standard hollow fiber membrane oxygenator (HFMO) in vivo during veno-venous extracorporeal life support for 24 hours in anesthetized, mechanically ventilated uninjured swine (n = 3/group). The objective was to assess feasibility, safety, and biocompatibility. Circuits remained patent and operated with stable pressures throughout 24 hours. No group differences in vital signs or evidence of end-organ damage occurred. No change in plasma free hemoglobin and von Willebrand factor multimer size distribution were observed. Platelet count decreased in BLOx at 6 hours (37% dec, P = 0.03), but not in HFMO; however, thrombin generation potential was elevated in HFMO (596 ± 81 nM·min) versus BLOx (323 ± 39 nM·min) at 24 hours (P = 0.04). Other coagulation and inflammatory mediator results were unremarkable. BLOx required higher mechanical ventilator settings and showed lower gas transfer efficiency versus HFMO, but the stable device performance indicates that this technology is ready for further performance scaling and testing in lung injury models and during longer use conditions.

3.
Am J Respir Crit Care Med ; 208(12): 1283-1292, 2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-37797214

RESUMEN

Rationale: Early post injury mitigation strategies in ARDS are in short supply. Treatments with allogeneic stromal cells are administered after ARDS develops, require specialized expertise and equipment, and to date have shown limited benefit. Objectives: Assess the efficacy of immediate post injury intravenous administration of autologous or allogeneic bone marrow-derived mesenchymal stromal cells (MSCs) for the treatment of acute respiratory distress syndrome (ARDS) due to smoke inhalation and burns. Methods: Yorkshire swine (n = 32, 44.3 ± 0.5 kg) underwent intravenous anesthesia, placement of lines, severe smoke inhalation, and 40% total body surface area flame burns, followed by 72 hours of around-the-clock ICU care. Mechanical ventilation, fluids, pressors, bronchoscopic cast removal, daily lung computed tomography scans, and arterial blood assays were performed. After injury and 24 and 48 hours later, animals were randomized to receive autologous concentrated bone marrow aspirate (n = 10; 3 × 106 white blood cells and a mean of 56.6 × 106 platelets per dose), allogeneic MSCs (n = 10; 6.1 × 106 MSCs per dose) harvested from healthy donor swine, or no treatment in injured control animals (n = 12). Measurements and Main Results: The intravenous administration of MSCs after injury and at 24 and 48 hours delayed the onset of ARDS in swine treated with autologous MSCs (48 ± 10 h) versus control animals (14 ± 2 h) (P = 0.004), reduced ARDS severity at 24 (P < 0.001) and 48 (P = 0.003) hours, and demonstrated visibly diminished consolidation on computed tomography (not significant). Mortality at 72 hours was 1 in 10 (10%) in the autologous group, 5 in 10 (50%) in the allogeneic group, and 6 in 12 (50%) in injured control animals (not significant). Both autologous and allogeneic MSCs suppressed systemic concentrations of TNF-α (tumor necrosis factor-α). Conclusions: The intravenous administration of three doses of freshly processed autologous bone marrow-derived MSCs delays ARDS development and reduces its severity in swine. Bedside retrieval and administration of autologous MSCs in swine is feasible and may be a viable injury mitigation strategy for ARDS.


Asunto(s)
Quemaduras , Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas , Síndrome de Dificultad Respiratoria , Porcinos , Animales , Médula Ósea , Síndrome de Dificultad Respiratoria/terapia , Síndrome de Dificultad Respiratoria/patología , Factor de Necrosis Tumoral alfa , Administración Intravenosa , Quemaduras/patología , Trasplante de Células Madre Mesenquimatosas/métodos
4.
Bio Protoc ; 13(18): e4814, 2023 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-37753473

RESUMEN

Device-induced thrombosis remains a major complication of extracorporeal life support (ECLS). To more thoroughly understand how blood components interact with the artificial surfaces of ECLS circuit components, assessment of clot deposition on these surfaces following clinical use is urgently needed. Scanning electron microscopy (SEM), which produces high-resolution images at nanoscale level, allows visualization and characterization of thrombotic deposits on ECLS circuitry. However, methodologies to increase the quantifiability of SEM analysis of ECLS circuit components have yet to be applied clinically. To address these issues, we developed a protocol to quantify clot deposition on ECLS membrane oxygenator gas transfer fiber sheets through digital and SEM imaging techniques. In this study, ECLS membrane oxygenator fiber sheets were obtained, fixed, and imaged after use. Following a standardized process, the percentage of clot deposition on both digital images and SEM images was quantified using ImageJ through blind reviews. The interrater reliability of quantitative analysis among reviewers was evaluated. Although this protocol focused on the analysis of ECLS membrane oxygenators, it is also adaptable to other components of the ECLS circuits such as catheters and tubing. Key features • Quantitative analysis of clot deposition using digital and scanning electron microscopy (SEM) techniques • High-resolution images at nanoscale level • Extracorporeal life support (ECLS) devices • Membrane oxygenators • Blood-contacting surfaces Graphical overview.

5.
ACS Appl Bio Mater ; 6(5): 1953-1959, 2023 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-37068205

RESUMEN

Coating all portions of an extracorporeal membrane oxygenation (ECMO) circuit with materials exhibiting inherent, permanent antithrombotic properties is an essential step to prevent thrombus-induced complications. However, developing antithrombotic coatings for oxygenator fibers within membrane oxygenators of ECMO systems has proven challenging. We have used polydopamine (PDA) to coat oxygenator fibers and immobilize a Cu-based metal-organic framework (MOF) on the surface to act as a nitric oxide (NO) catalyst. Importantly, the PDA/MOF coating will produce NO indefinitely from endogenous S-nitrosothiols and it has not previously been applied to ECMO oxygenator fibers.


Asunto(s)
Estructuras Metalorgánicas , Óxido Nítrico , Proyectos Piloto , Fibrinolíticos , Oxigenadores de Membrana
6.
Adv Sci (Weinh) ; 10(18): e2207455, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37092588

RESUMEN

Recent global events such as COVID-19 pandemic amid rising rates of chronic lung diseases highlight the need for safer, simpler, and more available treatments for respiratory failure, with increasing interest in extracorporeal membrane oxygenation (ECMO). A key factor limiting use of this technology is the complexity of the blood circuit, resulting in clotting and bleeding and necessitating treatment in specialized care centers. Microfluidic oxygenators represent a promising potential solution, but have not reached the scale or performance required for comparison with conventional hollow fiber membrane oxygenators (HFMOs). Here the development and demonstration of the first microfluidic respiratory assist device at a clinical scale is reported, demonstrating efficient oxygen transfer at blood flow rates of 750 mL min⁻1 , the highest ever reported for a microfluidic device. The central innovation of this technology is a fully 3D branching network of blood channels mimicking key features of the physiological microcirculation by avoiding anomalous blood flows that lead to thrombus formation and blood damage in conventional oxygenators. Low, stable blood pressure drop, low hemolysis, and consistent oxygen transfer, in 24-hour pilot large animal experiments are demonstrated - a key step toward translation of this technology to the clinic for treatment of a range of lung diseases.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , Animales , Humanos , Microfluídica , Pandemias , Oxígeno
7.
Am J Transplant ; 23(8): 1241-1255, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37119855

RESUMEN

The effect of using donation after circulatory death (DCD) hearts on waitlist outcomes has not been substantiated. We retrospectively analyzed 184 heart transplant (HT) candidates at our institution from 2019 to 2021. Patients were stratified into 2 observation periods centered on September 12, 2020, when the adult DCD HT program officially began. The primary outcome was a comparison of transplant rate between period 1 (pre-DCD) and period 2 (post-DCD). Secondary outcomes included waitlist time-to-transplant, waitlist mortality rate, independent predictors of incidence of HT, and posttransplant outcomes. A total of 165 HTs (n = 92 in period 1 and n = 73 in period 2) were performed. The median waitlist time-to-transplant decreased from 47.5 to 19 days in periods 1 and 2, respectively (P = .004). The transplant rate increased from 181 per 100 patient-years in period 1 to 579 per 100 patient-years in period 2 (incidence rate ratio, 1.87; 95% CI, 1.04-3.38; P = .038). There were no statistical differences in waitlist mortality rate (P = .566) and 1-year survival (P = .699) between the 2 periods. DCD HTs (n = 36) contributed to 49.3% of overall HT activity in period 2. We concluded that utilization of DCD hearts significantly reduced waitlist time and increased transplant rate. Short-term posttransplant outcomes were comparable between the pre-DCD and post-DCD periods.


Asunto(s)
Trasplante de Corazón , Trasplante de Hígado , Obtención de Tejidos y Órganos , Adulto , Humanos , Donantes de Tejidos , Estudios Retrospectivos , Muerte , Supervivencia de Injerto
8.
J Biomed Mater Res B Appl Biomater ; 111(4): 923-932, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36404401

RESUMEN

Numerous biomaterials have been developed for application in blood-contacting medical devices to prevent thrombosis; however, few materials have been applied to full-scale devices and evaluated for hemocompatibility under clinical blood flow conditions. We applied a dual-action slippery liquid-infused (LI) nitric oxide (NO)-releasing material modification (LINO) to full-scale blood circulation tubing for extracorporeal lung support and evaluated the tubing ex vivo using swine whole blood circulated for 6 h at a clinically relevant flow. LINO tubing was compared to unmodified tubing (CTRL) and isolated LI and NO-releasing modifications (n = 9/group). The primary objective was to evaluate safety and blood compatibility of this approach, prior to progression to in vivo testing of efficacy in animal models. The secondary objective was to evaluate coagulation outcomes relevant to hemocompatibility. No untoward effects of the coating, such as elevated methemoglobin fraction, were observed. Additionally, LINO delayed platelet loss until 6 h versus the reduction in platelet count in CTRL at 3 h. At 6 h, LINO significantly reduced the concentration of platelets in an activated P-selectin expressing state versus CTRL (32 ± 1% decrease, p = .02). Blood clot deposition was significantly reduced on LINO blood pumps (p = .007) and numerically reduced on tubing versus CTRL. Following blood exposure, LINO tubing continued to produce a measurable NO-flux (0.20 ± 0.06 × 10-10  mol cm-2  min-1 ). LINO is a potential solution to reduce circuit-related bleeding and clotting during extracorporeal organ support, pending future extended testing in vivo using full-scale extracorporeal lung support devices.


Asunto(s)
Óxido Nítrico , Trombosis , Animales , Porcinos , Óxido Nítrico/farmacología , Circulación Extracorporea , Plaquetas , Coagulación Sanguínea , Materiales Biocompatibles/farmacología , Trombosis/prevención & control
9.
Perfusion ; : 2676591221130175, 2022 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-36196521

RESUMEN

BACKGROUND: Patients with kidney failure are at risk for lethal complications from hyperkalemia. Resuscitation, medications, and hemodialysis are used to mitigate increased potassium (K+) levels in circulating blood; however, these approaches may not always be readily available or effective, especially in a resource limited environment. We tested a sorbent cartridge (KC, K+ontrol CytoSorbents Medical Inc., Monmouth Junction, New Jersey) which contains a resin adsorber for K+. The objective of this study was to test the utility of KC in an ex vivo circulation system. We hypothesized that KC reduces K+ levels in extracorporeal circulation of donor swine whole blood infused with KCl. METHODS: A six-hour circulation study was carried out using KC, a NxStage (NxStage Medical, Inc., Lawrence, MA) membrane, blood bag containing heparinized whole blood with KCl infusion, 3/16-inch ID tubing, a peristaltic pump, and flow sensors. The NxStage permeate line was connected back to the main circuit in the Control group (n = 6), creating a recirculation loop. For KC group (n = 6), KC was added to the recirculation loop, and a continuous infusion of KCl at 10 mEq/hour was administered for two hours. Blood samples were acquired at baseline and every hour for 6 h. RESULTS: In the control group, K+ levels remained at ∼9 mmol/L; 9.1 ± 0.4 mmol/L at 6 h. In the KC group, significant decreases in K+ at hour 1 (4.3 ± 0.3 mmol/L) and were sustained for the experiment duration equilibrating at 4.6 ± 0.4 mmol/L after 6 h (p = 0.042). Main loop blood flow was maintained under 400 mL/min; recirculation loop flow varied between 60 and 70 mL/min in the control group and 45-55 mL/min in the KC group. Decreases in recirculation loop flow in KC group required 7% increase of pump RPM. CONCLUSIONS: During ex-vivo extracorporeal circulation using donor swine blood, KC removed approximately 50% of K+, normalizing circulating levels.

10.
ASAIO J ; 68(10): 1312-1319, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-36194101

RESUMEN

Extracorporeal membrane oxygenation (ECMO) has been advancing rapidly due to a combination of rising rates of acute and chronic lung diseases as well as significant improvements in the safety and efficacy of this therapeutic modality. However, the complexity of the ECMO blood circuit, and challenges with regard to clotting and bleeding, remain as barriers to further expansion of the technology. Recent advances in microfluidic fabrication techniques, devices, and systems present an opportunity to develop new solutions stemming from the ability to precisely maintain critical dimensions such as gas transfer membrane thickness and blood channel geometries, and to control levels of fluid shear within narrow ranges throughout the cartridge. Here, we present a physiologically inspired multilayer microfluidic oxygenator device that mimics physiologic blood flow patterns not only within individual layers but throughout a stacked device. Multiple layers of this microchannel device are integrated with a three-dimensional physiologically inspired distribution manifold that ensures smooth flow throughout the entire stacked device, including the critical entry and exit regions. We then demonstrate blood flows up to 200 ml/min in a multilayer device, with oxygen transfer rates capable of saturating venous blood, the highest of any microfluidic oxygenator, and a maximum blood flow rate of 480 ml/min in an eight-layer device, higher than any yet reported in a microfluidic device. Hemocompatibility and large animal studies utilizing these prototype devices are planned. Supplemental Visual Abstract, http://links.lww.com/ASAIO/A769.


Asunto(s)
Biomimética , Microfluídica , Animales , Diseño de Equipo , Oxígeno , Oxigenadores
11.
ACS Biomater Sci Eng ; 8(8): 3438-3449, 2022 08 08.
Artículo en Inglés | MEDLINE | ID: mdl-35776832

RESUMEN

Medical devices that require substantial contact between blood and a foreign surface would be dramatically safer if constructed from materials that prevent clot formation and coagulation disturbance at the blood-biomaterial interface. Nitric oxide (NO), an endogenous inhibitor of platelet activation in the vascular endothelium, could provide anticoagulation at the blood-surface interface when applied to biomaterials. We investigated an application of a copper-based metal-organic framework, H3[(Cu4Cl)3(BTTri)8-(H2O)12]·72H2O where H3BTTri = 1,3,5-tris(1H-1,2,3-triazole-5-yl)benzene] (CuBTTri), which has been shown to be an effective catalyst to generate NO from S-nitrosothiols that are endogenously present in blood. A method was developed to apply a CuBTTri composite coating to Tygon medical tubing used for extracorporeal lung support devices. The stability and activity of the coating were evaluated during 72 h dynamic saline flow testing (1.5-2.5 L/min, n = 3) with scanning electron microscopy imaging and inductively coupled mass-spectroscopy analysis. Compatibility of the coating with whole blood was assessed with a panel of hemocompatibility tests during 6 h circulation of swine donor blood in an ex vivo circulation loop constructed with CuBTTri tubing or unmodified Tygon (1.5 L/min blood flow rate, n = 8/group). Thrombus deposition and catalytic activity of the CuBTTri tubing were assessed following blood exposure. The coating remained stable during 72 h saline flow experiments at clinically relevant flow rates. No adverse effects were observed relative to controls during blood compatibility testing, to include no significant changes in platelet count (p = 0.42), platelet activation indicated by P-selectin expression (p = 0.57), coagulation panel values, or methemoglobin fraction (p = 0.18) over the 6 h circulation period. CuBTTri within the coating generated NO following blood exposure in the presence of biologically relevant concentrations of an NO donor. CuBTTri composite coating was stable and blood compatible in this pilot study and requires further investigation of efficacy using in vivo models conducted with clinically relevant blood flow rates and study duration.


Asunto(s)
Estructuras Metalorgánicas , Trombosis , Animales , Materiales Biocompatibles , Estructuras Metalorgánicas/química , Estructuras Metalorgánicas/farmacología , Óxido Nítrico/química , Óxido Nítrico/metabolismo , Donantes de Óxido Nítrico , Proyectos Piloto , Porcinos , Trombosis/prevención & control
12.
Perfusion ; : 2676591221095469, 2022 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-35514052

RESUMEN

INTRODUCTION: Clot formation, infection, and biofouling are unfortunate but frequent complications associated with the use of blood-contacting medical devices. The challenge of blood-foreign surface interactions is exacerbated during medical device applications involving substantial blood contact area and extended duration of use, such as extracorporeal life support (ECLS). We investigated a novel surface modification, a liquid-impregnated surface (LIS), designed to minimize protein adsorption and thrombus development on medical plastics. METHODS: The hemocompatibility and efficacy of LIS was investigated first in a low-shear model with LIS applied to the lumen of blood incubation vials and exposed to human whole blood. Additionally, LIS was evaluated in a 6 h ex vivo circulation model with swine blood using full-scale ECLS circuit tubing and centrifugal pumps with clinically relevant flow rate (1.5 L/min) and shear conditions for extracorporeal carbon dioxide removal. RESULTS: Under low-shear, LIS preserved fibrinogen concentration in blood relative to control polymers (+40 ± 6 mg/dL vs polyvinyl chloride, p < .0001), suggesting protein adsorption was minimized. A fibrinogen adhesion assay demonstrated a dramatic reduction in protein adsorption under low shear (87% decrease vs polyvinyl chloride, p = .01). Thrombus deposition and platelet adhesion visualized by scanning electron microscopy were drastically reduced. During the 6 h ex vivo circulation, platelets in blood exposed to LIS tubing did not become significantly activated or procoagulant, as occurred with control tubing; and again, thrombus deposition was visually reduced. CONCLUSIONS: A LIS coating demonstrated potential to reduce thrombus formation on medical devices. Further testing is needed specialized to clinical setting and duration of use for specific medical target applications.

13.
ACS Appl Bio Mater ; 5(5): 2212-2223, 2022 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-35404571

RESUMEN

Multifunctional antithrombotic surface modifications for blood-contacting medical devices have emerged as a solution for foreign surface-mediated coagulation disturbance. Herein, we have developed and evaluated an endothelium-inspired strategy to reduce the thrombogenicity of medical plastics by imparting nitric oxide (NO) elution and heparin immobilization on the material surface. This dual-action approach (NO+Hep) was applied to polyethylene terephthalate (PET) blood incubation vials and compared to isolated modifications. Vials were characterized to evaluate NO surface flux as well as heparin density and activity. Hemocompatibility was assessed in vitro using whole blood from human donors. Compared to unmodified surfaces, blood incubated in the NO+Hep vials exhibited reduced platelet aggregation (15% decrease AUC, p = 0.040) and prolonged plasma clotting times (aPTT = 147% increase, p < 0.0001, prothrombin time = 5% increase, p = 0.0002). Prolongation of thromboelastography reaction time and elevated antifactor Xa levels in blood from NO+Hep versus PET vials suggests some heparin leaching from the vial surface, confirmed by post-blood incubation heparin density assessment. Results suggest NO+Hep surface modification is a promising approach for blood-contacting plastics; however, careful tuning of NO flux and heparin stabilization are essential and require assessment using human blood as performed here.


Asunto(s)
Coagulación Sanguínea , Heparina , Endotelio , Heparina/farmacología , Humanos , Óxido Nítrico , Plásticos
14.
Artif Organs ; 46(6): 1181-1191, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35289412

RESUMEN

BACKGROUND: Consumption of platelets and coagulation factors during extracorporeal carbon dioxide removal (ECCO2 R) increases bleeding complications and associated mortality. Regional infusion of lactic acid enhances ECCO2 R by shifting the chemical equilibrium from bicarbonate to carbon dioxide. Our goal was to test if regional blood acidification during ECCO2 R inhibits platelet function and coagulation. METHODS: An ECCO2 R system containing a hemofilter circulated blood at 0.25 L/min in eight healthy ewes (Ovis aries) for 36 h. Three of the sheep received ECCO2 R with no recirculation compared to five sheep that received ECCO2 R plus 12 h of regional blood acidification via the hemofilter, placed upstream from the oxygenator, into which 4.4 M lactic acid was infused. Blood gases, platelet count and function, thromboelastography, coagulation-factor activity, and von Willebrand factor activity (vWF:Ag) were measured at baseline, at start of lactic acid infusion, and after 36 h of extracorporeal circulation. RESULTS: Twelve hours of regional acid infusion significantly inhibited platelet aggregation response to adenosine diphosphate; vWF; and platelet expression of P-selectin compared to control. It also significantly reduced consumption of fibrinogen and of coagulation factors V, VII, IX, compared to control. CONCLUSIONS: Regional acidification reduces platelet activation and vitamin-K-dependent coagulation-factor consumption during ECCO2 R. This is the first report of a simple method that may enhance effective anticoagulation for ECCO2 R.


Asunto(s)
Dióxido de Carbono , Factor de von Willebrand , Animales , Plaquetas , Circulación Extracorporea , Femenino , Concentración de Iones de Hidrógeno , Ácido Láctico/farmacología , Ovinos
15.
J Spec Oper Med ; 22(1): 64-69, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35278316

RESUMEN

BACKGROUND: We assessed the use of an FDA-cleared transport ventilator with limited functions and settings during ground transport in a swine model of ground evacuation. We hypothesized that when used as an adjunct to extracorporeal life support (ECLS), the device would enable safe mobile ventilatory support during ground evacuation. METHODS: Female Yorkshire swine (n = 11; mean, 52.4 ± 1.3 kg) were sedated and anesthetized and received mechanical ventilation (MV) with a standard intensive care unit (ICU) ventilator and were transitioned to the Simplified Automated Ventilator II (SAVe II; AutoMedx) during ground transport. MV served as an adjunct to ECLS in all animals. Ventilator performance was assessed in the uninjured state on day 1 and after bilateral pulmonary contusion on day 2. Data were collected pre- and post-transport on both days. RESULTS: During 33 transports, the SAVe II provided similar ventilation support as the ICU ventilator. Mean total transport time was 38.8 ± 2.1 minutes. The peak inspiratory pressure (PIP) limit was the only variable to show consistent differences pre- and post-transport and between ventilators. No adverse events occurred. CONCLUSION: As an adjunctive supportive device during ground transport, the SAVe II performed adequately without failure or degradation in subject status. Further testing is warranted to elucidate the clinical limits of this device during standalone use.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Respiración Artificial , Animales , Cuidados Críticos , Femenino , Humanos , Unidades de Cuidados Intensivos , Porcinos , Ventiladores Mecánicos
16.
Biomolecules ; 12(1)2022 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-35053249

RESUMEN

Several preclinical and clinical reports have demonstrated that levels of circulating high mobility group box 1 protein (HMGB1) are increased early after trauma and are associated with systemic inflammation and clinical outcomes. However, the mechanisms of the interaction between HMGB1 and inflammatory mediators that lead to the development of remote organ damage after trauma remain obscure. HMGB1 and inflammatory mediators were analyzed in plasma from 54 combat casualties, collected on admission to a military hospital in Iraq, and at 8 and 24 h after admission. In total, 45 (83%) of these patients had traumatic brain injury (TBI). Nine healthy volunteers were enrolled as controls. HMGB1 plasma levels were significantly increased in the first 8 h after admission, and were found to be associated with systemic inflammatory responses, injury severity score, and presence of TBI. These data provided the rationale for designing experiments in rats subjected to blast injury and hemorrhage, to explore the effect of HMGB1 inhibition by CX-01 (2-O, 3-O desulfated heparin). Animals were cannulated, then recovered for 5-7 days before blast injury in a shock tube and volume-controlled hemorrhage. Blast injury and hemorrhage induced an early increase in HMGB1 plasma levels along with severe tissue damage and high mortality. CX-01 inhibited systemic HMGB1 activity, decreased local and systemic inflammatory responses, significantly reduced tissue and organ damage, and tended to increase survival. These data suggest that CX-01 has potential as an adjuvant treatment for traumatic hemorrhage.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Proteína HMGB1 , Animales , Lesiones Traumáticas del Encéfalo/metabolismo , Proteína HMGB1/metabolismo , Humanos , Inflamación/metabolismo , Ratas
17.
Perfusion ; 37(3): 242-248, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-33567967

RESUMEN

INTRODUCTION: Extracorporeal life support (ECLS) patients are at risk for complications caused by gaseous microemboli (GME). GMEs can cause hypoxia, inflammation, coagulation, and end-organ damage. The objective of this in vitro study was to assess dynamics of GME formation during circulation of whole blood or a glycerol blood surrogate. We hypothesized that there is no difference in GME counts and sizes between whole blood and the glycerol blood surrogate and that the membrane lung reduces GME counts over time. METHODS: A circulation platform was developed using the Cardiohelp ECLS system to run either donor blood or glycerol solution. We conducted 10 repetitions consisting of three phases of ultrasound GME detection using the EDAC™ Quantifier (Luna Innovations, Charlottesville, VA, USA) for each group. Phases were 3-minute recordings at the initiation of 2 L/min flow (Phase 1), post-injection of a GME suspension (Phase 2), and 10 minutes after injection (Phase 3). The number and size of GME pre- and post-ML were recorded separately and binned based on diameter ranges. RESULTS: In Phase 1, GME count in blood was higher than in glycerol. In Phase 2, there was a large increase in GME counts; however, most GME were reduced post-membrane in both groups. In Phase 3, there was a significant decrease in GME counts compared to Phase 2. GME > 100 µm in glycerol decreased post membrane. CONCLUSIONS: We demonstrated GME formation and decay dynamics during in vitro circulation in an ECLS system with blood and glycerol. GME counts were higher in blood, likely due to varying rheological properties. There were decreases in GME levels post membrane in both groups after GME injection, with the membrane lung effectively trapping the GME, and additional reduction 10 minutes after GME injection.


Asunto(s)
Embolia Aérea , Circulación Extracorporea , Oxigenación por Membrana Extracorpórea , Puente Cardiopulmonar , Embolia Aérea/etiología , Diseño de Equipo , Oxigenación por Membrana Extracorpórea/efectos adversos , Gases , Glicerol , Humanos , Sistemas de Manutención de la Vida
18.
Micromachines (Basel) ; 12(8)2021 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-34442512

RESUMEN

The recent emergence of microfluidic extracorporeal lung support technologies presents an opportunity to achieve high gas transfer efficiency and improved hemocompatibility relative to the current standard of care in extracorporeal membrane oxygenation (ECMO). However, a critical challenge in the field is the ability to scale these devices to clinically relevant blood flow rates, in part because the typically very low blood flow in a single layer of a microfluidic oxygenator device requires stacking of a logistically challenging number of layers. We have developed biomimetic microfluidic oxygenators for the past decade and report here on the development of a high-flow (30 mL/min) single-layer prototype, scalable to larger structures via stacking and assembly with blood distribution manifolds. Microfluidic oxygenators were designed with biomimetic in-layer blood distribution manifolds and arrays of parallel transfer channels, and were fabricated using high precision machined durable metal master molds and microreplication with silicone films, resulting in large area gas transfer devices. Oxygen transfer was evaluated by flowing 100% O2 at 100 mL/min and blood at 0-30 mL/min while monitoring increases in O2 partial pressures in the blood. This design resulted in an oxygen saturation increase from 65% to 95% at 20 mL/min and operation up to 30 mL/min in multiple devices, the highest value yet recorded in a single layer microfluidic device. In addition to evaluation of the device for blood oxygenation, a 6-h in vitro hemocompatibility test was conducted on devices (n = 5) at a 25 mL/min blood flow rate with heparinized swine donor blood against control circuits (n = 3). Initial hemocompatibility results indicate that this technology has the potential to benefit future applications in extracorporeal lung support technologies for acute lung injury.

19.
ASAIO J ; 67(7): 798-808, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33534236

RESUMEN

Coagulopathic complications during extracorporeal life support (ECLS) result from two parallel processes: 1) foreign surface contact and shear stress during blood circulation and 2) administration of anticoagulant drugs to prevent circuit thrombosis. To address these problems, biocompatible surfaces are developed to prevent foreign surface-induced coagulopathy, reducing or eliminating the need for anticoagulants. Tethered liquid perfluorocarbon (TLP) is a nonadhesive coating that prevents adsorption of plasma proteins and thrombus deposition. We examined application of TLP to complete ECLS circuits (membranes, tubing, pumps, and catheters) during 72 hours of ECLS in healthy swine (n = 5/group). We compared TLP-coated circuits used without systemic anticoagulation to standard of care: heparin-coated circuits with continuous heparin infusion. Coagulopathic complications, device performance, and systemic effects were assessed. We hypothesized that TLP reduces circuit thrombosis and iatrogenic bleeding, without impeding gas exchange performance or causing untoward effects. No difference in bleeding or thrombotic complication rate was observed; however, circuit occlusion occurred in both groups (TLP = 2/5; CTRL = 1/5). TLP required elevated sweep gas rate to maintain normocapnia during ECLS versus CTRL (10-20 vs. 5 L/min; p = 0.047), suggesting impaired gas exchange. Thrombus deposition and protein adhesion on explanted membranes were comparable, and TLP did not preserve platelet or blood cell counts relative to controls. We conclude that neither TLP nor standard of care is an efficacious solution to prevent coagulation disturbances during ECLS. Further testing of promising biomaterials for ECLS utilizing the model outlined here is warranted.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Animales , Anticoagulantes/efectos adversos , Coagulación Sanguínea/efectos de los fármacos , Circulación Extracorporea , Oxigenación por Membrana Extracorpórea/efectos adversos , Fluorocarburos/farmacología , Heparina/farmacología , Porcinos
20.
Scand J Trauma Resusc Emerg Med ; 29(1): 8, 2021 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-33407759

RESUMEN

BACKGROUND: In this review, we assess the state of Resuscitative Endovascular Occlusion of the Aorta (REBOA) today with respect to out-of-hospital (OOH) vs. inhospital (H) use in blunt and penetrating trauma, as well as discuss areas of promising research that may be key in further advancement of REBOA applications. METHODS: To analyze the trends in REBOA use, we conducted a review of the literature and identified articles with human or animal data that fit the respective inclusion and exclusion criteria. In separate tables, we compiled data extracted from selected articles in categories including injury type, zone and duration of REBOA, setting in which REBOA was performed, sample size, age, sex and outcome. Based on these tables as well as more detailed review of some key cases of REBOA usage, we assessed the current state of REBOA as well as coagulation and histological disturbances associated with its usage. All statistical tests were 2-sided using an alpha=0.05 for significance. Analysis was done using SAS 9.5 (Cary, NC). Tests for significance was done with a t-test for continuous data and a Chi Square Test for categorical data. RESULTS: In a total of 44 cases performed outside of a hospital in both military and civilian settings, the overall survival was found to be 88.6%, significantly higher than the 50.4% survival calculated from 1,807 cases of REBOA performed within a hospital (p<.0001). We observe from human data a propensity to use Zone I in penetrating trauma and Zone III in blunt injuries. We observe lower final metabolic markers in animal studies with shorter REBOA time and longer follow-up times. CONCLUSIONS: Further research related to human use of REBOA must be focused on earlier initiation of REBOA after injury which may depend on development of rapid vascular access devices and techniques more so than on any new improvements in REBOA. Future animal studies should provide detailed multisystem organ assessment to accurately define organ injury and metabolic burden associated with REBOA application. Overall, animal studies must involve realistic models of injury with severe clinical scenarios approximating human trauma and exsanguination, especially with long-term follow-up after injury.


Asunto(s)
Aorta , Oclusión con Balón , Servicios Médicos de Urgencia , Procedimientos Endovasculares , Heridas no Penetrantes/terapia , Heridas Penetrantes/terapia , Femenino , Humanos , Masculino , Heridas no Penetrantes/complicaciones , Heridas Penetrantes/complicaciones
SELECCIÓN DE REFERENCIAS